Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38401593

RESUMEN

Sneddon's syndrome (SS) manifests through multiple strokes and livedo reticularis. Livedoid vasculopathy (VL) is characterized by a long history of foot and leg ulceration and histopathology indicating a thrombotic process. Arterial retinal branch occlusion is described in a 52-year-old male with VL. He did not present noticeable laboratory abnormalities, such as antiphospholipid antibodies, or a history of strokes. Retinal artery occlusion accompanied by VL could be a variant of Sneddon's syndrome. Optical coherence tomography angiography revealed a reduction in the macula's vascular layers in the asymptomatic eye, indicating localized microvascular changes as an evolving marker in the pathogenesis of SS.

2.
Arch. Soc. Esp. Oftalmol ; 98(12): 680-686, dic. 2023. ilus, tab, graf
Artículo en Español | IBECS | ID: ibc-228143

RESUMEN

Propósito Evaluar la capacidad diagnóstica de la densidad de vasos (DV) papilar y macular mediante angiografía por tomografía de coherencia óptica (OCTA) y el grosor de la capa de fibras nerviosas de la retina (CFNR) y complejo de células ganglionares (CCG) maculares mediante tomografía de coherencia óptica (OCT) en los pacientes con glaucoma seudoexfoliativo (GPX). Métodos Estudio transversal que incluyó GPX y controles sanos. Se realizó OCT y OCTA de la papila y el área macular con el OCT RS-3000 Advance (Nidek Co., Gamagori, Japón). Se registró la DV macular del plexo capilar superficial (SCP) y la DV papilar del plexo capilar peripapilar radial (RPCP). Se empleó el área bajo la curva característica operativa del receptor (AUROC) para determinar el poder discriminatorio de cada parámetro. Resultados El grosor de la CFNR y del CCG, así como la DV a nivel papilar y macular, fueron significativamente menores en los pacientes con GPX que en los controles sanos (todos, p<0,05). El mejor parámetro discriminante fue el grosor medio de la CFNR (AUROC: 0,928). El AUROC de la DV papilar fue mejor que el de la DV macular (AUROC: 0,897 y 0,780, respectivamente). AUROC de la DV papilar fue comparable a la del grosor de la CFNR (p<0,001).Conclusiones La capacidad diagnóstica de la DV papilar en el GPS parece comparable a la de los parámetros estructurales, espesor de la CFNR y CCG, obtenidos mediante OCT, por lo que la OCTA podría ser una herramienta valiosa en el GPX. (AU)


PurposeTo evaluate the diagnostic ability of the vessel density (VD) of the optic nerve head (ONH) and the macula on optical coherence tomography (OCT) angiography and the retinal nerve layer thickness (RNFL) thickness and the macular ganglion cell complex (GCC) thickness on OCT in patients with pseudoexfoliative glaucoma (PXG). Methods Cross-sectional study including PXG patients and healthy controls. Demographic and clinical data were noted for all participants. Optical coherence tomography (OCT) and OCT angiography (OCTA) images of the ONH and macular area were obtained with the RS-3000 Advance OCT (Nidek Co., Gamagori, Japan). The RNFL and GCC thickness of different sectors was provided by the software. Macular VD of the superficial capillary plexus (SCP) and ONH VD of the radial peripapillary capillary plexus (RPCP) were registered. Groups were compared and area under the receiver operating characteristic (AUROC) curves were used to determine the power of discrimination of each parameter. Results RNFL and GCC thickness and ONH and macular VD were significantly lower in PXG patients compared with healthy controls (all, P<.05). The best discrimination parameter was the average RNFL thickness (AUROC: 0.928). ONH VD AUROC was better than that of macular VD (AUROC: 0.897 and 0.780, respectively). ONH VD AUROC was comparable to RNFL thickness (P<.001).Conclusions The diagnostic ability of ONH vessel density in PXG appears comparable to that of the structural parameters, RNFL and GCC thickness, obtained with OCT, and may be a valuable tool in clinical practice. (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Tomografía de Coherencia Óptica , Glaucoma/diagnóstico por imagen , Glaucoma/patología , Sensibilidad y Especificidad , Estudios Transversales
3.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(12): 680-686, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37788756

RESUMEN

PURPOSE: To evaluate the diagnostic ability of the vessel density (VD) of the optic nerve head (ONH) and the macula on optical coherence tomography (OCT) angiography and the retinal nerve layer thickness (RNFL) thickness and the macular ganglion cell complex (GCC) thickness on OCT in patients with pseudoexfoliative glaucoma (PXG). METHODS: Cross-sectional study including PXG patients and healthy controls. Demographic and clinical data were noted for all participants. Optical coherence tomography (OCT) and OCT angiography (OCTA) images of the ONH and macular area were obtained with the RS-3000 Advance OCT (Nidek Co., Gamagori, Japan). The RNFL and GCC thickness of different sectors was provided by the software. Macular VD of the superficial capillary plexus (SCP) and ONH VD of the radial peripapillary capillary plexus (RPCP) were registered. Groups were compared and area under the receiver operating characteristic (AUROC) curves were used to determine the power of discrimination of each parameter. RESULTS: RNFL and GCC thickness and ONH and macular VD were significantly lower in PXG patients compared with healthy controls (all, p<0.05). The best discrimination parameter was the average RNFL thickness (AUROC: 0.928). ONH VD AUROC was better than that of macular VD (AUROC: 0.897 and 0.780, respectively). ONH VD AUROC was comparable to RNFL thickness (p<0.001). CONCLUSIONS: The diagnostic ability of ONH vessel density in PXG appears comparable to that of the structural parameters, RNFL and GCC thickness, obtained with OCT, and may be a valuable tool in clinical practice.


Asunto(s)
Glaucoma de Ángulo Abierto , Glaucoma , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Disco Óptico/irrigación sanguínea , Tomografía de Coherencia Óptica/métodos , Glaucoma de Ángulo Abierto/diagnóstico , Estudios Transversales , Presión Intraocular , Vasos Retinianos/diagnóstico por imagen , Glaucoma/diagnóstico por imagen
4.
Arch. Soc. Esp. Oftalmol ; 98(10): 595-600, oct. 2023. ilus
Artículo en Español | IBECS | ID: ibc-226093

RESUMEN

Caso clínico Mujer de 48años con escotomas superotemporales persistentes y fotopsias de 2meses de evolución y zonas despigmentadas en retina de ambos ojos con patrón trizonal en imagen multimodal. La resonancia magnética cerebral, la tomografía por emisión de positrones, los anticuerpos antirretinianos y los marcadores inmunológicos, infecciosos y tumorales fueron negativos, por lo que se diagnosticó retinopatía externa oculta zonal aguda. La paciente fue tratada con adalimumab. Sin embargo, 19meses después los síntomas aumentaron y se detectó progresión en la angiografía por tomografía de coherencia óptica, así como también en la prueba de campo visual Humphrey y el electrorretinograma, por lo que se agregó micofenolato de mofetilo, mostrando mejoría y estabilización de la enfermedad durante un seguimiento de 4años. Discusión La angiografía por tomografía de coherencia óptica puede ser una herramienta potencial para monitorizar la progresión y la respuesta al tratamiento además de otras modalidades de imagen en la retinopatía externa oculta zonal aguda, y la combinación de adalimumab y micofenolato puede ser útil en la enfermedad recurrente (AU)


Clinical case A 48-year-old woman with persistent superotemporal scotomas and photopsias for 2months, and depigmented zones in the retina of both eyes with a trizonal pattern on multimodal imaging. Brain magnetic resonance imaging, positron emission tomography, antiretinal antibodies and immunological, infectious and tumor markers tests were negative, thus acute zonal occult outer retinopathy was diagnosed. Patient was treated with adalimumab. Nevertheless, 19months later symptoms increased, and progression was detected on optic coherence tomography angiography, as well as in Humphrey visual field test and electroretinogram, thus, mycophenolate mofetil was added showing improvement and stabilization of the disease in a 4-year follow-up. Discussion Optic coherence tomography angiography may be a potential tool to monitor progression and response to treatment in addition to other imaging modalities in acute zonal occult outer retinopathy, and the combination of adalimumab and mycophenolate may be useful in recurrent disease (AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Retinopatía Hipertensiva/diagnóstico por imagen , Tomografía de Coherencia Óptica , Angiografía por Tomografía Computarizada , Enfermedad Aguda
5.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(10): 595-600, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37364680

RESUMEN

CLINICAL CASE: A 48-year-old woman with persistent superotemporal scotomas and photopsias for 2 months, and depigmented zones in the retina of both eyes with a trizonal pattern on multimodal imaging. Brain magnetic resonance imaging, positron emission tomography, antiretinal antibodies, immunological, infectious and tumor markers tests were negative, thus acute zonal occult outer retinopathy was diagnosed. Patient was treated with adalimumab. Nevertheless, 19 months later symptoms increased, and progression was detected on optic coherence tomography angiography, as well as in Humphrey visual field test and electroretinogram, thus, mycophenolate mofetil was added showing improvement and stabilization of the disease in a 4-year follow-up. DISCUSSION: Optic coherence tomography angiography may be a potential tool to monitor progression and response to treatment in addition to other imaging modalities in acute zonal occult outer retinopathy, and the combination of adalimumab and mycophenolate may be useful in recurrent disease.


Asunto(s)
Escotoma , Tomografía de Coherencia Óptica , Femenino , Humanos , Persona de Mediana Edad , Escotoma/diagnóstico por imagen , Escotoma/etiología , Adalimumab/uso terapéutico , Tomografía de Coherencia Óptica/métodos , Angiografía con Fluoresceína/métodos
6.
Arch. Soc. Esp. Oftalmol ; 98(6): 317-324, jun. 2023.
Artículo en Español | IBECS | ID: ibc-221222

RESUMEN

Objetivo Evaluar la reproducibilidad de la densidad vascular (DV) peripapilar, cabeza del nervio óptico (ONH-PP) y área macular mediante angiografía por tomografía de coherencia óptica de dominio espectral (SD OCT-A) en pacientes con glaucoma y en sujetos sanos. Métodos Estudio transversal que evaluó 63 ojos de 63 sujetos, incluyendo 33 pacientes con glaucoma y 30 sujetos sanos. El glaucoma se clasificó en leve, moderado o avanzado. Dos exploraciones consecutivas fueron adquiridas por Spectralis Module OCT-A (Heidelberg, Alemania) y proporcionaron imágenes del complejo vascular superficial (SVC), del plexo vascular de la capa de fibra nerviosa (NFLVP) y del plexo vascular superficial (SVP); del complejo vascular profundo (DVC), del plexo capilar intermedio (ICP) y del plexo capilar profundo (DCP). La DV (%) fue calculada mediante AngioTool. Se calcularon los coeficientes de correlación intraclase (ICC) y los coeficientes de variación (CV). Resultados Respecto a la DV de ONH-PP, el mejor ICC lo presentó el glaucoma avanzado (0,86-0,96) y moderado (0,83-0,97) en comparación con el glaucoma leve (0,64-0,86). Para la DV macular, los resultados de ICC para las capas retinianas superficiales fueron mejores para el glaucoma leve (0,94-0,96), seguido por el glaucoma moderado (0,88-0,93) y por el avanzado (0,85-0,91), y para las capas retinianas más profundas el ICC fue más alto para el glaucoma moderado (0,95-0,96), seguido por el glaucoma avanzado (0,80-0,86) y por el leve (0,74-0,91). Los CV oscilaron entre el 2,2% y el 10,94%. Entre los sujetos sanos, los ICC para las mediciones de DV ONH-PP (0,91-0,99) y para las mediciones de la DV macular (0,93-0,97) fueron excelentes en todas las capas, con CV del 1,65% al 10,33% (AU)


Objective To assess the reproducibility of peripapillary, optic nerve head (ONH-PP) and macular vessel density (VD) by spectral domain optical coherence tomography angiography (SD OCT-A) in glaucoma patients and healthy subjects. Methods Cross-sectional study assessing 63 eyes of 63 subjects, including 33 glaucoma patients and 30 healthy subjects. Glaucoma was classified in mild, moderate, or advanced. Two consecutive scans were acquired by spectralis module OCT-A (Heidelberg, Germany), and provided images of the superficial vascular complex (SVC), nerve fiber layer vascular plexus (NFLVP), superficial vascular plexus (SVP), deep vascular complex (DVC), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). VD (%) was calculated by AngioTool. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated. Results Among ONH-PP VD, better ICC presented advanced (0.86-0.96) and moderate glaucoma (0.83-0.97) compared with mild glaucoma (0.64-0.86). For the macular VD reproducibility, ICC results for superficial retinal layers were better for mild glaucoma (0.94-0.96) followed by moderated (0.88-0.93) and advanced glaucoma (0.85-0.91), and for deeper retinal layers ICC was better for moderate glaucoma (0,95-0,96) followed by advanced (0.80-0.86) and mild glaucoma (0.74-0.91). CVs ranged from 2.2%% to 10.94%. Among healthy subjects, ICCs for the ONH-PP VD measurements (0.91-0.99) and for the macular VD measurements (0.93-0.97) were excellent in all layers, with CVs from 1.65% to 10.33%. Conclusions SD OCT-A used to quantify macular and ONH-PP VD showed excellent and good reproducibility in most layers of the retina, both in healthy subjects and in glaucoma patients regardless of the severity of the disease (AU)


Asunto(s)
Humanos , Glaucoma/diagnóstico por imagen , Nervio Óptico/diagnóstico por imagen , Mácula Lútea/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica
7.
Arch. Soc. Esp. Oftalmol ; 98(5): 270-275, mayo 2023. graf, tab
Artículo en Español | IBECS | ID: ibc-219935

RESUMEN

Propósito Evaluar cambios en la densidad vascular (VD) mediante la angiografía por tomografía de coherencia óptica (OCTA) en los diferentes sectores maculares de pacientes con retinitis pigmentosa (RP) y controles. Métodos Estudio observacional de 22 casos y 21 controles. Se reclutan 22 pacientes con RP y 21 controles. Se obtienen imágenes de tamaño 6×6 del área macular mediante Angio-OCT SS-DRI-Triton 1.22 (Topcon, Japón), desechando las imágenes con mala calidad. Se recoge agudeza visual, biomicroscopía, campo visual y tomografía de coherencia óptica (OCT) estructural. El área macular se divide en 4 sectores (nasal, superior, inferior y temporal), y se comparan los valores de VD entre ambos grupos en los plexos superficial (SVP) y profundo (DVP). Se estudia también la correlación entre la VD y el grosor macular. Resultados Diez pacientes con RP se desecharon por mala calidad de imagen. Se analizan 12 pacientes con RP y 21 controles sanos. El índice de campo visual (VFI) medio en el grupo RP fue del 26,11% (±17,29). La VD fue significativamente inferior en el grupo RP comparado con los controles en todos los sectores maculares del DVP (Superior 43,48±3,79 vs. 48,86±2,62; p<0,0001; Nasal 40,52±4,30 vs. 46,01±3,23; p=0,0002; Inferior 42,76±5,26 vs. 50,10±3,36; p<0,0001; Temporal 40,42±4,46 vs. 46,09±2,91; p=0,0001) y en todos menos en el sector nasal en el SVP (Superior 39,86±4,46 vs. 46,47±2,61; p<0,0001; Nasal 40,35±4,56 vs. 44,09±2,87; p=0,0067; Inferior 40,74±4,61 vs. 46,58±3,26; p=0,0002; Temporal 39,98±5,07 vs. 44,78±3,28; p=0,0024). La correlación entre la VD y el grosor macular se mostró positiva y significativa (RP: r=0,59; p=0,043; controles r=0,51; p=0,018). Conclusiones Los pacientes con formas avanzadas de RP muestran menor VD en el área macular que los controles sanos. Estas diferencias están presentes en todos los cuadrantes del DVP y en 3 de ellos en el SVP (AU)


Aims To describe the changes in vessel density (VD) using optical coherence tomography angiography (OCTA) of the different sectors in the macular area between retinitis pigmentosa (RP) patients and controls. Methods Observational case-control study. We initially included 22 patients with RP and 21 controls. We obtained 6x6 OCTA images of the macular area using Angio-OCT SS-DRI-Triton 1.22 (Topcon, Japan), together with visual acuity, biomicroscopy, visual field and optical coherence tomography examination. We compared the VD values in both groups for both superficial (SVP) and deep vascular plexus (DVP). Correlation between VD and macular thickness was also calculated. Results The mean visual field index (VFI) in the RP group was 26.11% (±17.29). VD was significantly lower in the RP group compared with healthy controls in all sectors of the DVP (Superior 43.48±3.79 vs 48.86±2.62, P<.0001; Nasal 40,52±4.30 vs 46,01±3.23, P=.0002; Inferior 42.76±5.26 vs 50.10±3.36, P<.0001; Temporal 40.42±4.46 vs 46.09±2.91, P=.0001) and in all but nasal sector in the SVP (Superior 39.86±4.46 vs 46.47±2.61, P<.0001; Nasal 40.35±4.56 vs 44.09±2.87, P=.0067; Inferior 40.74±4.61 vs 46.58±3.26, P=.0002; Temporal 39.98±5.07 vs 44.78±3.28, P=.0024). Correlation between VD and macular thickness was positive and significant (RP: r=.59, P=.043; controls r=.51, P=.018). Conclusions Patients with advanced forms of RP have less vessel density in the macular area than healthy subjects. These differences are present in all four quadrants in the DVP and three in the SVP (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Retinitis Pigmentosa/diagnóstico por imagen , Tomografía de Coherencia Óptica , Estudios de Casos y Controles , Angiografía
8.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(6): 317-324, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37023850

RESUMEN

OBJECTIVE: To assess the reproducibility of peripapillary, optic nerve head (PP-ONH) and macular vessel density (VD) by Spectral Domain optical coherence tomography angiography (SD OCT-A) in glaucoma patients and healthy subjects. METHODS: Cross-sectional study assessing 63 eyes of 63 subjects, including 33 glaucoma patients and 30 healthy subjects. Glaucoma was classified in mild, moderate, or advanced. Two consecutive scans were acquired by Spectralis Module OCT-A (Heidelberg, Germany), and provided images of the superficial vascular complex (SVC), nerve fiber layer vascular plexus (NFLVP), superficial vascular plexus (SVP); deep vascular complex (DVC), intermediate capillary plexus (ICP) and deep capillary plexus (DCP). VD (%) was calculated by AngioTool. Intraclass correlation coefficients (ICCs) and coefficients of variation (CV) were calculated. RESULTS: Among PP-ONH VD, better ICC presented advanced (ICC 0.86-0.96) and moderate glaucoma (ICC 0.83-0.97) compared with mild glaucoma (0.64-0.86). For the macular VD reproducibility, ICC results for superficial retinal layers were better for mild glaucoma (0.94-0.96) followed by moderated (0.88-0.93) and advanced glaucoma (0.85-0.91), and for deeper retinal layers ICC was better for moderate glaucoma (0.95-0.96) followed by advanced (0.80-0.86) and mild glaucoma (0.74-0.91). CVs ranged from 2.2% to 10.94%. Among healthy subjects, ICCs for the PP-ONH VD measurements (0.91-0.99) and for the macular VD measurements (0.93-0.97) were excellent in all layers, with CVs from 1.65% to 10.33%. CONCLUSIONS: SD OCT-A used to quantify macular and PP-ONH VD showed excellent and good reproducibility in most layers of the retina, both in healthy subjects and in glaucoma patients regardless of the severity of the disease.


Asunto(s)
Glaucoma , Mácula Lútea , Disco Óptico , Humanos , Disco Óptico/diagnóstico por imagen , Disco Óptico/irrigación sanguínea , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Reproducibilidad de los Resultados , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Mácula Lútea/diagnóstico por imagen , Mácula Lútea/irrigación sanguínea , Glaucoma/diagnóstico por imagen
9.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(5): 270-275, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37031736

RESUMEN

AIMS: To describe the changes in vessel density (VD) using optical coherence tomography angiography (OCTA) of the different sectors in the macular area between retinitis pigmentosa (RP) patients and controls. METHODS: Observational case-control study. We initially included 22 patients with RP and 21 controls. We obtained 6 × 6 OCTA images of the macular area using Angio-OCT SS-DRI-Triton 1.22 (Topcon, Japan), together with visual acuity, biomicroscopy, visual field and optical coherence tomography examination. We compared the VD values in both groups for both superficial (SVP) and deep vascular plexus (DVP). Correlation between VD and macular thickness was also calculated. RESULTS: The mean visual field index (VFI) in the RP group was 26.11% (±17.29). VD was significantly lower in the RP group compared with healthy controls in all sectors of the DVP (Superior 43.48 ±â€¯3.79 vs 48.86 ±â€¯2.62, P < .0001; Nasal 40,52 ±â€¯4.30 vs 46,01 ±â€¯3.23, P = .0002; Inferior 42.76 ±â€¯5.26 vs 50.10 ±â€¯3.36, P < .0001; Temporal 40.42 ±â€¯4.46 vs 46.09 ±â€¯2.91, P = .0001) and in all but nasal sector in the SVP (Superior 39.86 ±â€¯4.46 vs 46.47 ±â€¯2.61, P < .0001; Nasal 40.35 ±â€¯4.56 vs 44.09 ±â€¯2.87, P = .0067; Inferior 40.74 ±â€¯4.61 vs 46.58 ±â€¯3.26, P = .0002; Temporal 39.98 ±â€¯5.07 vs 44.78 ±â€¯3.28, P = .0024). Correlation between VD and macular thickness was positive and significant (RP: r = 0.59, P = .043; controls r = 0.51, P = .018). CONCLUSIONS: Patients with advanced forms of RP have less vessel density in the macular area than healthy subjects. These differences are present in all four quadrants in the DVP and three in the SVP.


Asunto(s)
Vasos Retinianos , Retinitis Pigmentosa , Humanos , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Estudios de Casos y Controles , Benchmarking , Retinitis Pigmentosa/diagnóstico por imagen
10.
Arch. Soc. Esp. Oftalmol ; 98(3): 125-131, mar. 2023.
Artículo en Español | IBECS | ID: ibc-216819

RESUMEN

Introducción y objetivos Investigar el efecto de la acetazolamida (AZ) sobre la microvasculatura ocular retiniana y coroidea en la mácula y los capilares peripapilares radiales (CPR) del disco óptico con angiografía-OCT (OCTA). Materiales y métodos Estudio transversal observacional de 9meses de duración. Se reclutaron 45 ojos de 45 participantes sanos que se sometieron a cirugía de cataratas. Se comparó la densidad de vasos (DV) de la retina macular y la coriocapilar (CC) y la DV de la CPR en la zona del disco óptico antes y 60 min después de administrar 250mg de AZ por vía oral. También se midieron la presión intraocular (PIO) y la presión arterial (PA) sistémica antes de cada exploración. Resultado La edad media era de 73,1±6,9 años. La densidad de vasos (DV) en el plexo capilar superficial (PCS) y profundo (PCP) de la retina y la CC en el área macular no mostraron cambios significativos (p>0,5, para todos los parámetros). La DV en los CPR no mostró cambios significativos con la AZ (p>0,5, para todos los parámetros). El grosor foveal y parafoveal aumentó de 248,98 (± 23,89) a 250,33 (± 23,74) y de 311,62 (± 16,53) a 311,98 (± 16,38) (p<0,001 y p=0,046), respectivamente. La PIO disminuyó de 13,2 (± 3,0) mmHg a 11,8 (± 3,2) mmHg (p<0,001), mientras que la PA sistólica y diastólica disminuyó de 144,8 (± 21,8) a 137,7 (± 19,0) y de 80,0 (± 12,7) a 76,2 (± 11,7) (p=0,021 y p=0,030), respectivamente. Conclusiones Las imágenes de OCTA no revelaron cambios significativos en la VD del disco óptico ni en el VD de la retina y la coroides en la mácula con AZ oral una hora después de su administración en participantes por lo demás sanos que se sometieron a cirugía de cataratas (AU)


Introduction and objectives To investigate the effect of acetazolamide (AZ) on the retinal and choroidal ocular microvasculature in the macula and radial peripapillary capillaries (RPC) of the optic disc with OCT Angiography (OCTA). Materials and method Nine-month observational cross-sectional study. Forty-five eyes from 45 healthy participants who underwent cataract surgery were recruited. Macular retina and choriocapillaris vessel density (VD) and RPC VD in the optic disc area were compared before and 60minutes after 250mg acetazolamide per os. Intraocular pressure (IOP) and systemic blood pressure (BP) were also measured before each scan. Result Mean age was 73.1±6.9 years. VDs in the superficial (SCP) and deep (DCP) capillary plexus of the retina and the choriocapillaris (CC) in the macular area showed no significant change (p>0.5, for all parameters). VD in the RPC showed no significant change with AZ (p>0.5, for all parameters). Foveal and parafoveal thickness increased from 248.98 (±23.89) to 250.33 (±23.74) and from 311.62 (±16.53) to 311.98 (±16.38) (p<0.001 and p=0.046), respectively. IOP decreased from 13.2 (±3.0) mmHg to 11.8 (±3.2) mmHg (p<0.001), while systolic and diastolic BP decreased from 144.8 (±21.8) to 137.7 (±19.0) and from 80.0 (±12.7) to 76.2 (±11.7) (p=0.021 and p=0.030), respectively. Conclusion OCTA imaging did not reveal any significant changes in the VD of the optic disc or the retinal and choroidal VD in the macula with oral AZ one hour after its administration in otherwise healthy participants who underwent cataract surgery (AU)


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Acetazolamida/farmacología , Inhibidores de Anhidrasa Carbónica/farmacología , Vasos Retinianos/efectos de los fármacos , Disco Óptico/efectos de los fármacos , Coroides/efectos de los fármacos , Estudios Transversales , Tomografía de Coherencia Óptica , Angiografía por Tomografía Computarizada , Vasos Retinianos/diagnóstico por imagen , Disco Óptico/diagnóstico por imagen , Coroides/diagnóstico por imagen
11.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(3): 125-131, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36738925

RESUMEN

INTRODUCTION AND OBJECTIVES: To investigate the effect of acetazolamide (AZ) on the retinal and choroidal ocular microvasculature in the macula and radial peripapillary capillaries (RPC) of the optic disc with OCT Angiography (OCTA). MATERIALS AND METHODS: Nine-month observational cross-sectional study. Forty-five eyes from 45 healthy participants who underwent cataract surgery were recruited. Macular retina and choriocapillaris vessel density (VD) and RPC VD in the optic disc area were compared before and 60min after 250mg acetazolamide per os. Intraocular pressure (IOP) and systemic blood pressure (BP) were also measured before each scan. RESULTS: Mean age was 73.1±6.9 years. VDs in the superficial (SCP) and deep (DCP) capillary plexus of the retina and the choriocapillaris (CC) in the macular area showed no significant change (P>.5, for all parameters). VD in the RPC showed no significant change with AZ (P>.5, for all parameters). Foveal and parafoveal thickness increased from 248.98 (±23.89) to 250.33 (±23.74) and from 311.62 (±16.53) to 311.98 (±16.38) (P<.001 and P=.046), respectively. IOP decreased from 13.2 (±3.0) mmHg to 11.8 (±3.2) mmHg (P<.001), while systolic and diastolic BP decreased from 144.8 (±21.8) to 137.7 (±19.0) and from 80.0 (±12.7) to 76.2 (±11.7) (P=.021 and P=.030), respectively. CONCLUSIONS: OCTA imaging did not reveal any significant changes in the VD of the optic disc or the retinal and choroidal VD in the macula with oral AZ one hour after its administration in otherwise healthy participants who underwent cataract surgery.


Asunto(s)
Catarata , Disco Óptico , Humanos , Anciano , Anciano de 80 o más Años , Disco Óptico/irrigación sanguínea , Acetazolamida , Angiografía con Fluoresceína/métodos , Vasos Retinianos , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Coroides/irrigación sanguínea
12.
Arch. Soc. Esp. Oftalmol ; 97(8): 432-442, ago. 2022. ilus, tab
Artículo en Español | IBECS | ID: ibc-209093

RESUMEN

Objetivos Desarrollar y evaluar un método automático de medición del área de la zona avascular foveal (ZAF) en ojos sanos en angiografía por tomografía de coherencia óptica de dominio espectral Heidelberg (HS-OCTA). Este método se denomina Macro Kanno-Saitama modificado (KSMm) y es una evolución de la aproximación Macro Kanno-Saitama (KSM). Métodos Este estudio transversal incluyó 29 ojos de 25 voluntarios sanos a los que se les realizaron dos HS-OCTA de la zona macular en el mismo momento. Se incluyeron todas las imágenes a pesar de su calidad. Los datos de la zona macular del plexo vascular superficial, del plexo capilar intermedio (PCI) y del plexo capilar profundo fueron procesados usando KSMm. El área ZAF se midió dos veces automáticamente usando KSMm y KSM y dos veces manualmente por dos examinadores independientes. Resultados De 174 imágenes, KSM no pudo medir correctamente el 31%, mientras que KSMm pudo medir con éxito todas las imágenes. El coeficiente intraclase intraescaneo varió entre 0,948 y 0,993 para medidas manuales y fue 1 con el método KSMm. Aunque según los gráficos de Bland-Altman la diferencia entre examinadores humanos es menor que entre examinadores humanos y KSMm, los gráficos de dispersión muestran una fuerte correlación entre las medidas realizadas por humanos y las automáticas. Los mejores resultados se obtienen en PCI. Conclusiones Usando KSMm, la medida automática del área ZAF en HS-OCTA es factible y menos humano-dependiente. Resuelve la incapacidad de KSM de medir el área ZAF en imágenes de calidad subóptima que son frecuentes en la práctica clínica diaria. Por lo tanto, el procesamiento KSMm podría contribuir a nuestra comprensión de los tres plexos vasculares (AU)


Purpose To develop and evaluate an automated method to measure the foveal avascular zone (FAZ) area in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography (HS-OCTA). This method is referred to as the modified Kanno-Saitama macro (mKSM) which is an evolution of the Kanno-Saitama macro (KSM) approach. Methods This cross-sectional study included 29 eyes of 25 healthy volunteers who underwent HS-OCTA at the macular area twice at the same time. Regardless of the quality of the images, all of them were included. Macular data on the superficial vascular plexus, intermediate capillary plexus (ICP) and deep capillary plexus were processed by mKSM. The FAZ area was measured twice automatically using the mKSM and KSM and twice manually by two independent examiners. Results From 174 images, KSM could not measure correctly 31% while mKSM could successfully measure all of them. Intrascan intraclass coefficient ranged from 0.948 to 0.993 for manual measurements and was 1 for mKSM method. Despite that the difference between human examiners is smaller than between human examiners and mKSM according to Bland-Altman plots, the scatterplots show a strong correlation between human and automatic measurements. The best results are obtained in ICP. Conclusions With mKSM, the automated determination of the FAZ area in HS-OCTA is feasible and less human-dependent. It solves the inability of KSM to measure the FAZ area in suboptimal quality images which are frequent in daily clinical practice. Therefore, the mKSM processing could contribute to our understanding of the three vascular plexuses (AU)


Asunto(s)
Humanos , Fóvea Central/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Estudios Transversales , Angiografía con Fluoresceína/métodos , Vasos Retinianos/diagnóstico por imagen
13.
Arch Soc Esp Oftalmol (Engl Ed) ; 97(8): 432-442, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35680537

RESUMEN

PURPOSE: To develop and evaluate an automated method to measure the foveal avascular zone (FAZ) area in healthy eyes on Heidelberg Spectralis Optical Coherence Tomography Angiography (HS-OCTA). This method is referred to as the modified Kanno-Saitama macro (mKSM) which is an evolution of the Kanno-Saitama macro (KSM) approach. METHODS: This cross-sectional study included 29 eyes of 25 healthy volunteers who underwent HS-OCTA at the macular area twice at the same time. Regardless of the quality of the images, all of them were included. Macular data on the superficial vascular plexus, intermediate capillary plexus (ICP) and deep capillary plexus were processed by mKSM. The FAZ area was measured twice automatically using the mKSM and KSM and twice manually by two independent examiners. RESULTS: From 174 images, KSM could not measure correctly 31% while mKSM could successfully measure all of them. Intrascan intraclass coefficient ranged from 0,948 to 0,993 for manual measurements and was 1 for mKSM method. Despite that the difference between human examiners is smaller than between human examiners and mKSM according to Bland-Altman plots, the scatterplots show a strong correlation between human and automatic measurements. The best results are obtained in ICP. CONCLUSIONS: With mKSM, the automated determination of the FAZ area in HS-OCTA is feasible and less human-dependent. It solves the inability of KSM to measure the FAZ area in suboptimal quality images which are frequent in daily clinical practice. Therefore, the mKSM processing could contribute to our understanding of the three vascular plexuses.


Asunto(s)
Fóvea Central , Tomografía de Coherencia Óptica , Estudios Transversales , Angiografía con Fluoresceína/métodos , Fóvea Central/diagnóstico por imagen , Humanos , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
14.
Arch. Soc. Esp. Oftalmol ; 96(12): 663-667, dic. 2021. ilus, tab
Artículo en Español | IBECS | ID: ibc-218364

RESUMEN

Un melanocitoma del disco óptico es una lesión neoplásica pigmentada y benigna que en promedio mide 2,00mm de diámetro. Melanocitomas del disco óptico más pequeños son raros y no han sido estudiados con múltiples técnicas de imagen. Un caso de un «micromelanocitoma» del disco óptico con un diámetro de 0,71mm fue estudiado con múltiples estudios de imagen, incluyendo autofluorescencia de fondo de ojo, ultrasonido ocular, campos visuales, tomografía de coherencia óptica (OCT) y angiografía por OCT. Mientras que la exploración con biomicroscopia y la autoflourescencia de fondo de ojo revelan cambios compatibles con los casos de tamaño promedio previamente publicados, la OCT, angiografía por OCT y el ultrasonido revelan cambios que difieren de los artículos previos y que podrían ser útiles para el seguimiento (AU)


An optic disk melanocytoma is a benign pigmented neoplasm of the optic disk measuring 2.00mm of diameter in average. Smaller optic disk melanocytomas are rare and have not been studied with multiple imaging studies. A case of a “micro” optic disk melanocytoma measuring 0.71mm in diameter was studied by multiple imaging modalities, including fundus autofluorescence, ultrasound, visual fields, optical coherence tomography (OCT) and OCT angiography. While clinical appreciation and fundus autofluorescence reveal changes compatible with previously reported cases, OCT, OCT angiography and ultrasound reveal specific changes that could be useful for follow up (AU)


Asunto(s)
Humanos , Femenino , Adulto , Disco Óptico/diagnóstico por imagen , Neoplasias del Nervio Óptico/diagnóstico por imagen , Melanoma/diagnóstico por imagen , Tomografía de Coherencia Óptica , Angiografía con Fluoresceína , Imagen Multimodal
15.
Arch Soc Esp Oftalmol (Engl Ed) ; 96(12): 663-667, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34844688

RESUMEN

An optic disk melanocytoma is a benign pigmented neoplasm of the optic disk measuring 2.00 mm of diameter in average. Smaller optic disk melanocytomas are rare and have not been studied with multiple imaging studies. A case of a "micro" optic disk melanocytoma measuring 0.71 mm in diameter was studied by multiple imaging modalities, including fundus autofluorescence, ultrasound, visual fields, optical coherence tomography (OCT) and OCT angiography. While clinical appreciation and fundus autofluorescence reveal changes compatible with previously reported cases, OCT, OCT angiography and ultrasound reveal specific changes that could be useful for follow up.


Asunto(s)
Disco Óptico , Neoplasias del Nervio Óptico , Angiografía con Fluoresceína , Humanos , Imagen Multimodal , Disco Óptico/diagnóstico por imagen , Neoplasias del Nervio Óptico/diagnóstico por imagen , Tomografía de Coherencia Óptica
16.
Arch Soc Esp Oftalmol (Engl Ed) ; 96(8): 449-452, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34340786

RESUMEN

Two cases are reported of acute idiopathic blind spot enlargement syndrome (AIBSE) that presented with peripapillary white spots in the fundus. AIBSE belongs to the acute zonal occult outer retinopathy (AZOOR) complex. Conditions of this AZOOR complex may overlap. Typically, in AIBSE, a peripapillary hyperautofluorescence is seen in the autofluorescence. En-face OCT angiography at the ellipsoid level showed hyper-reflective spots around the optic disk in both cases. One case showed a reversible enlargement of the blind spot in visual field. AZOOR complex is an inflammatory disorder that affects the outer retina, and can now be confirmed with structural optical coherence tomography. In the cases presented, there was a reversible severe loss of the outer retina.


Asunto(s)
Síndromes de Puntos Blancos , Angiografía con Fluoresceína , Humanos , Imagen Multimodal , Escotoma , Agudeza Visual , Síndromes de Puntos Blancos/diagnóstico por imagen
17.
Arch. Soc. Esp. Oftalmol ; 96(8): 449-452, ago. 2021. ilus
Artículo en Español | IBECS | ID: ibc-218021

RESUMEN

Presentamos dos casos clínicos ilustrativos con imagen multimodal de síndrome de aumento idiopático de mancha ciega (SAIMC), que debutan con puntos blancos peripapilares en el fondo de ojo. El SAIMC se engloba dentro del complejo de retinopatía zonal aguda oculta externa (AZOOR), solapándose en muchas ocasiones diferentes entidades dentro de este complejo. La hiperautofluorescencia en estos casos es típicamente peripapilar. En el en-face de la angiografía por OCT (A-OCT), a nivel de la capa de los elipsoides, se observan puntos hiperreflectivos peripapilares en ambos casos. En uno de ellos disponemos del campo visual que muestra aumento de mancha ciega reversible. El complejo AZOOR tiene en común la afectación de la retina externa que actualmente podemos demostrar con el OCT estructural. En ambos casos se observa una afectación de las capas externas que se recuperan progresivamente (AU)


Two cases are reported of acute idiopathic blind spot enlargement syndrome (AIBSE) that presented with peripapillary white spots in the fundus. AIBSE belongs to the acute zonal occult outer retinopathy (AZOOR) complex. Conditions of this AZOOR complex may overlap. Typically, in AIBSE, a peripapillary hyperautofluorescence is seen in the autofluorescence. En-face OCT angiography at the ellipsoid level showed hyper-reflective spots around the optic disk in both cases. One case showed a reversible enlargement of the blind spot in visual field. AZOOR complex is an inflammatory disorder that affects the outer retina, and can now be confirmed with structural optical coherence tomography. In the cases presented, there was a reversible severe loss of the outer retina (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Escotoma/diagnóstico , Disco Óptico , Angiografía con Fluoresceína , Tomografía de Coherencia Óptica , Imagen Multimodal , Agudeza Visual , Síndrome
18.
Gac Med Mex ; 157(2): 160-166, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34270531

RESUMEN

INTRODUCTION: Different optical coherence tomography angiography (OCTA) scanning protocols evaluate the macula. OBJECTIVE: To compare the determination coefficients (R2) between vessel and perfusion densities of two OCTA scanning protocols in order to determine if their metrics could be interchanged. METHOD: Cross-sectional, prospective, comparative, observational, study between two OCTA scanning protocols (Angioplex, Zeiss) in healthy subjects. The R2 between central, inner, and full densities (3 x 3 mm protocol) and between central, inner, outer and full densities (6 x 6 mm protocol) was identified, both for vessel and perfusion densities. RESULTS: Seventy-eight eyes were evaluated; subjects' median age was 23 years. There were high R2 between inner and full densities with the 3 x 3 mm protocol (0.96), between outer and full densities with the 6 x 6 mm protocol (0.96), and between central vessel and perfusion densities (≥ 0.96); R2 between central vessel and perfusion densities of different protocols was ≤ 0.71. CONCLUSIONS: Vessel and perfusion densities have high determination coefficients within a scanning protocol, but not between protocols, given that each one preferentially measures different macular areas. Metrics from different protocols should not be interchanged for follow up.


INTRODUCCIÓN: Distintos protocolos de angiotomografía de coherencia óptica evalúan la mácula. OBJETIVO: R2 entre las densidades vascular y de perfusión de dos protocolos de angiotomografía de coherencia óptica, para determinar si sus mediciones podían intercambiarse. MÉTODO: Estudio observacional, comparativo, prospectivo, transversal entre dos protocolos de angiotomografía de coherencia óptica (AngioPlex, Zeiss) en sujetos sanos. Se identificó la R2 entre las densidades vascular y de perfusión central, interna y completa (protocolo de 3 x 3 mm), y central, interna, externa y completa (protocolo de 6 x 6 mm). RESULTADOS: 78 ojos, mediana de edad 23 años. Hubo R2 altas entre las densidades interna y completa del protocolo de 3 x 3 mm (0.96), externa y completa del de 6 x 6 mm (0.96), y centrales vasculares y de perfusión (≥ 0.96); la R2 entre las densidades centrales vascular y de perfusión de distintos protocolos fue ≤ 0.71. CONCLUSIONES: Las densidades vasculares y de perfusión tienen R2 alta dentro de un protocolo, pero no entre protocolos, porque estos miden preferentemente zonas distintas, lo cual limita intercambiar mediciones.


Asunto(s)
Angiografía/métodos , Mácula Lútea/irrigación sanguínea , Tomografía de Coherencia Óptica/métodos , Adulto , Vasos Sanguíneos/diagnóstico por imagen , Estudios Transversales , Femenino , Voluntarios Sanos , Humanos , Mácula Lútea/diagnóstico por imagen , Masculino , Estudios Prospectivos , Flujo Sanguíneo Regional/fisiología , Estadísticas no Paramétricas , Agudeza Visual , Adulto Joven
19.
Gac. méd. Méx ; 157(2): 166-173, mar.-abr. 2021. tab, graf
Artículo en Español | LILACS | ID: biblio-1279097

RESUMEN

Resumen Introducción: Distintos protocolos de angiotomografía de coherencia óptica evalúan la mácula. Objetivo: R2) entre las densidades vascular y de perfusión de dos protocolos de angiotomografía de coherencia óptica, para determinar si sus mediciones podían intercambiarse. Método: Estudio observacional, comparativo, prospectivo, transversal entre dos protocolos de angiotomografía de coherencia óptica (AngioPlex, Zeiss) en sujetos sanos. Se identificó la R2 entre las densidades vascular y de perfusión central, interna y completa (protocolo de 3 x 3 mm), y central, interna, externa y completa (protocolo de 6 x 6 mm). Resultados: 78 ojos, mediana de edad 23 años. Hubo R2 altas entre las densidades interna y completa del protocolo de 3 x 3 mm (0.96), externa y completa del de 6 x 6 mm (0.96), y centrales vasculares y de perfusión (≥ 0.96); la R2 entre las densidades centrales vascular y de perfusión de distintos protocolos fue ≤ 0.71. Conclusiones: Las densidades vasculares y de perfusión tienen R2 alta dentro de un protocolo, pero no entre protocolos, porque estos miden preferentemente zonas distintas, lo cual limita intercambiar mediciones.


Abstract Introduction: Different optical coherence tomography angiography (OCTA) scanning protocols evaluate the macula. Objective: To compare the determination coefficients (R2) between vessel and perfusion densities of two OCTA scanning protocols, to learn whether their metrics could be interchanged. Method: Non-experimental, comparative, prospective, observational, cross-sectional study, between two OCTA scanning protocols (Angioplex, Zeiss) in healthy subjects. We found the R2 between central, inner, and full densities (3 x 3 mm protocol), and between central, inner, outer and full densities (6 x 6 mm protocol), both for vessel and perfusion densities. Results: 78 eyes, median age 23 years. There were high R2 between inner and full densities in the 3 x 3 mm protocol (0.96), between outer and full densities in the 6 x 6 mm protocol (0.96) and between central vessel and perfusion densities (≥0.96); R2 between central vessel and perfusion densities of different protocols (≤0.71). Conclusions: Vessel and perfusion densities have high determination coefficients within a scanning protocol, but not between protocols, because each preferentially measures different macular areas. The metrics of different protocols should not be interchanged for follow-up.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Adulto Joven , Angiografía/métodos , Tomografía de Coherencia Óptica/métodos , Mácula Lútea/irrigación sanguínea , Flujo Sanguíneo Regional/fisiología , Vasos Sanguíneos/diagnóstico por imagen , Agudeza Visual , Estudios Transversales , Estudios Prospectivos , Estadísticas no Paramétricas , Voluntarios Sanos , Mácula Lútea/diagnóstico por imagen
20.
Arch. Soc. Esp. Oftalmol ; 96(4): 214-218, abr. 2021. ilus, tab
Artículo en Español | IBECS | ID: ibc-217605

RESUMEN

La introducción de la angiografía por tomografía de coherencia óptica (OCT-A) ha generado interés en evaluar las alteraciones vasculares en la cabeza del nervio óptico para el diagnóstico y monitorización del glaucoma. El propósito de este estudio es comparar la perfusión del disco óptico entre sujetos normales y sujetos con glaucoma usando OCT-A para detectar cambios en la perfusión del disco óptico. El sistema OCTA AngioVue examinó 40 ojos de 40 pacientes (20 con glaucoma y 20 controles sanos). La densidad de flujo peripapilar radial total (4,5×4,5mm) se midió en diferentes niveles de segmentación. El estudio demostró que el flujo vascular peripapilar de la OCT-A y la exploración de la cabeza del nervio óptico fue mejor en los ojos normales en comparación con los pacientes con glaucoma. Esta revisión proporciona un resumen exhaustivo de las aplicaciones actuales y potenciales más importantes de OCTA en el glaucoma (AU)


The introduction of optical coherence tomography angiography (OCT-A) has generated interest in evaluating vascular dysfunctions in the optic nerve head for the diagnosis and monitoring of glaucoma. The purpose of this study is to compare perfusion of the optic disc between normal subjects and subjects with glaucoma using OCT-A in order to detect changes in perfusion of the optic disc. Using the OCT-A AngioVue® system, an examination was performed on 40 eyes of 40 patients (20 with glaucoma and 20 healthy controls). Total radial peripapillary flow density (4.5×4.5mm) was measured at different levels of segmentation. The study demonstrated that the peripapillary vascular flow of OCT-A and exploration of the optic nerve head was better in the normal eyes compared to glaucoma patients. This review provides a comprehensive summary of the most important current and potential applications of OCT-A in glaucoma (AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Glaucoma/diagnóstico por imagen , Nervio Óptico/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Tomografía de Coherencia Óptica , Estudios de Casos y Controles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...